This is a quick reference for how to use the diagnostic mode built into the C2J, the dual zone digital climate control system which came installed in some 1997 through 2003 Pontiac Grand Prix Models.

When I still had my 1999 Grand Prix, any time I wanted to look this up I always had trouble remembering the terms I need to search for to retrieve it, so I stole mirrored this from This Forum Post and tried to clean it up a little.

Enter diagnostics mode:

Press and hold both the Driver and Passenger knobs in simultaneously until the display changes to read “-00”.

To change position, turn the Driver knob to the desired number and turn the Passenger knob one click to view the data for that position.

To return to normal operation, press the MODE button next to the Passenger temperature knob.

Position Description Observed Values
-00 Error Codes List of Trouble Codes Below
-01 (servo position) 103-107
-02 (servo position) 128
-03 (servo position) 150
-04 CJ2 Fan Speed Low=15, 29, 44, 58, 71, 86, 110=High, CJ2 Unit will adjust to other increments as needed
-05 (servo position) 93 88-191
-06 (servo position) -152 00-252
-07 (servo position) 00 0, 34-255
-08 (servo position) -155 00-255
-09 (servo position) 00 0, 23-255
-10 ? 04 04
-11 CJ2 Vent Mode 1=Def, 2=Bilevel, 3=Auto, 4=Lower, 5=Def+Lower
-12 Engine Coolant Temp -60 degrees 80=104, 95=131, 100=140 Peak@135°F
-13 Actual Vehicle Speed in MPH 88
-14 (servo position) 00 21=0
-15 ? 39 44
-16 Radiator low fan turn on temp -106 207
-17 Radiator low fan turn off temp 196 199
-18 ? 50 51
-19 (servo position) 162-169 40-172
-20 Affected by cabin temp sensor 89 50-172
-21 (servo position) 00
-22 Sunload Sensor -117 LIGHT=126, 218=DARK

Trouble Codes

Trouble Code Description
00 No System Fault
01 or 101 Inside Air Temperature Sensor Short
02 or 102 Inside Air Temperature Sensor Open
03 or 103 Ambient Outside Temperature Sensor Short
04 or 104 Ambient Outside Temperature Sensor Open
05 or 105 LH Electric Actuator Open or Short
06 or 106 RH Electric Actuator Open or Short
07 or 107 UART Serial Data Line Fault
08 or 108 Solar Sensor Open

To Clear codes, press the A/C Mode button. A two digit code indicates a current fault A three digit code indicates a historic fault.